Written notice within 21 days of determination (§ 1910.95(g)(8))
N/A
Statutory Legal & Regulatory Analysis: 29 CFR § 1910.95, Occupational Safety and Health Act of 1970 § 6
What is the difference between OSHA's Action Level and Permissible Exposure Limit (PEL) for noise?
Under OSHA 29 CFR § 1910.95, the Action Level is an 8-hour Time-Weighted Average (TWA) of 85 dBA (equivalent to a 50% noise dose). Reaching the Action Level legally mandates the employer to implement an ongoing Hearing Conservation Program, conduct baseline and annual audiometric testing, provide training, and make hearing protectors available. The Permissible Exposure Limit (PEL) is an 8-hour TWA of 90 dBA (100% dose). Exceeding the PEL mandates the implementation of feasible engineering and administrative noise controls, and strictly requires employee use of hearing protection.
How does OSHA calculate noise dose and 8-hour TWA using the 5 dBA exchange rate?
OSHA utilizes a 5 dBA exchange rate (doubling rate), where allowable exposure time halves for every 5 dBA increase above 90 dBA (e.g., 90 dBA = 8 hrs, 95 dBA = 4 hrs, 100 dBA = 2 hrs). Noise dose is calculated under Appendix A as D = 100 * sum(C_i / T_i), where C_i is actual exposure time and T_i is permissible duration T_i = 8 / 2^((L - 90)/5). The 8-hour TWA is then computed as TWA = 16.61 * log10(D / 100) + 90.
What constitutes a Standard Threshold Shift (STS) and what are the employer's legal obligations?
Under 29 CFR § 1910.95(g)(10), a Standard Threshold Shift (STS) is a change in hearing threshold relative to the baseline audiogram of an average of 10 dB or more at 2000, 3000, and 4000 Hz in either ear. If an STS is confirmed, the employer must inform the employee in writing within 21 calendar days, retrain the employee, fit or refit hearing protectors with higher attenuation, and record the STS on OSHA Form 300 if work-related.
How must employers evaluate hearing protector attenuation under OSHA regulations?
Under 29 CFR § 1910.95 Appendix B and OSHA field guidance, when assessing whether hearing protectors provide adequate attenuation down to 90 dBA (or 85 dBA for employees who have experienced an STS), the laboratory Noise Reduction Rating (NRR) must be adjusted. When using A-weighted sound levels, OSHA instructs employers to subtract 7 dB from the NRR and apply a 50% safety derating factor: Effective Reduction = (NRR - 7) / 2.