Statutory Framework: OSHA 29 CFR § 1910.38
Under the Occupational Safety and Health Act of 1970, employers must provide safe working conditions free from recognized hazards. Standard 29 CFR § 1910.38 establishes the baseline federal requirements for workplace Emergency Action Plans (EAPs). An EAP organizes employer and employee actions during workplace emergencies, including fires, toxic chemical releases, and natural disasters.
Written Requirement vs The 10-Employee Oral Exemption
Under 29 CFR § 1910.38(b), any employer maintaining more than 10 employees at a facility must possess a formal written plan. The written plan must be maintained at the workplace and readily accessible to all employees for review at all times. Only employers with 10 or fewer employees are permitted to communicate the plan orally to employees.
The 6 Mandatory Statutory Components (§ 1910.38(c))
An EAP must contain at least the following six elements to survive OSHA inspection scrutiny:
- Reporting Procedures (§ 1910.38(c)(1)): Clear protocols for reporting fires or other emergencies (e.g., manual pull stations, 911 dispatch, internal security).
- Evacuation Policies & Route Assignments (§ 1910.38(c)(2)): Detailed emergency escape procedures and primary/secondary exit route assignments.
- Critical Operations Shutdown (§ 1910.38(c)(3)): Specific procedures for employees who remain behind to operate or secure critical machinery before evacuating.
- Headcount Accounting Procedures (§ 1910.38(c)(4)): A systematic procedure to account for all employees, contractors, and visitors after evacuation to designated assembly areas.
- Rescue and Medical Duties (§ 1910.38(c)(5)): Explicit identification of employees assigned to perform rescue or medical assistance (or an affirmative statement that outside emergency responders handle all rescue).
- Contact Personnel (§ 1910.38(c)(6)): Names or job titles of individuals who can be contacted for further information or clarification about plan duties.
Employee Training Mandates (§ 1910.38(e)) & OSHA Penalties
An EAP is legally defective if employees are not trained on its contents. Employers must review the plan with every worker: (1) when the plan is initially developed or when a new employee is hired; (2) when the employee's responsibilities or designated actions change; and (3) whenever the plan is amended. Under current OSHA penalty structures, failing to implement or maintain a conforming EAP where required routinely triggers "Serious" citations, carrying maximum statutory civil penalties exceeding $16,000 per violation.
Frequently Asked Questions: OSHA 29 CFR § 1910.38 EAPs
When does an employer require a written Emergency Action Plan under OSHA § 1910.38?
Under 29 CFR § 1910.38(b), an emergency action plan must be in writing, kept in the workplace, and available to employees for review. An exception applies only to employers with 10 or fewer employees, who may communicate the plan orally to employees.
What are the 6 minimum mandatory elements of an OSHA Emergency Action Plan?
Under 29 CFR § 1910.38(c), an EAP must at minimum include: (1) procedures for reporting a fire or other emergency; (2) procedures for emergency evacuation and exit route assignments; (3) procedures for employees who remain to operate critical plant operations; (4) procedures to account for all employees after evacuation; (5) procedures for employees performing rescue or medical duties; and (6) the name or job title of contact persons.
What are the employee training requirements under 29 CFR § 1910.38(e)?
An employer must designate and train employees to assist in a safe and orderly evacuation. The employer must review the EAP with each employee when the plan is developed or the employee is initially assigned, when the employee's responsibilities under the plan change, and whenever the plan is revised.
What alarm system standards apply under an OSHA Emergency Action Plan?
Under 29 CFR § 1910.38(d), an employer must establish an employee alarm system that complies with 29 CFR § 1910.165, providing distinctive tactile, audible, or visual signals that are perceptible above ambient workplace noise levels.