OSHA 29 CFR § 1910.212 Machine Guarding & Anchoring Auditor

Point of Operation Guarding, Table O-10 Barrier Spacing, and Stationary Machine Anchor Compliance

Machine & Barrier Specifications

OSHA Audit & Table O-10 Results

Max Permissible Opening (Table O-10): -- Inches
Actual Guard Opening: -- Inches
Table O-10 Barrier Clearance Status: --

Point of Operation & Nip Hazard Audit (§ 1910.212(a))

Point of Operation Protection: --
Rotating Parts / Nip Guarding: --
Flying Chip / Spark Deflector: --

Fixed Machine Anchoring Audit (§ 1910.212(b))

Floor / Bench Anchoring Compliance: --
Overall OSHA 1910.212 Compliance: --

OSHA Table O-10 Distance vs. Opening Standards

Distance from Danger Zone Max Opening Permitted Clearance Objective
1/2" to 1 1/2" 1/4" (0.250") Prevents finger tip penetration
1 1/2" to 2 1/2" 3/8" (0.375") Prevents finger entry
2 1/2" to 3 1/2" 1/2" (0.500") Prevents hand reaching point of operation
3 1/2" to 5 1/2" 5/8" (0.625") Restricts hand passage
5 1/2" to 6 1/2" 3/4" (0.750") Restricts wrist passage
6 1/2" to 7 1/2" 7/8" (0.875") Restricts forearm entry
7 1/2" to 12 1/2" 1 1/4" (1.250") Restricts arm extension
12 1/2" to 15 1/2" 1 1/2" (1.500") Restricts deep reach
15 1/2" to 17 1/2" 1 7/8" (1.875") Prevents full arm reach
17 1/2" to 31 1/2" 2 1/8" (2.125") Body clearance safety barrier

Frequently Asked Regulatory Questions

What are the universal machine guarding mandates under 29 CFR § 1910.212(a)(1)?

Under 29 CFR § 1910.212(a)(1), one or more methods of machine guarding must be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks. Examples of guarding methods include barrier guards, two-hand tripping devices, and electronic safety presence-sensing devices.

What is Table O-10 and how does it determine guard opening clearances?

OSHA Table O-10 specifies the maximum permissible opening size in a barrier guard based on its physical distance from the hazard zone (point of operation). For example, at a distance of 1/2 to 1 1/2 inches, the maximum allowable opening is 1/4 inch; at 2 1/2 to 3 1/2 inches, the opening may be up to 1/2 inch; and at 17 1/2 to 31 1/2 inches, the maximum opening is 2 1/8 inches to prevent body parts from reaching the danger zone.

Which machines are required to be permanently anchored under § 1910.212(b)?

Under 29 CFR § 1910.212(b), machines designed for a fixed location must be securely anchored to the floor, bench, or foundation to prevent walking or moving during operation. This mandatory standard routinely applies to drill presses, pedestal grinders, bench grinders, milling machines, power shears, and band saws.

What specific machines always require point of operation guarding under § 1910.212(a)(3)(iv)?

Section 1910.212(a)(3)(iv) explicitly lists machines that usually require point of operation guarding: guillotine cutters, shears, alligator shears, power presses, milling machines, power saws, jointers, portable power tools, and forming rolls and calendars.

What are the requirements for two-hand trip safety devices?

Two-hand tripping devices must be designed and installed so that both hands of the operator are concurrently engaged on the operating controls during the dangerous portion of the machine cycle, located far enough away from the hazard to prevent the operator from reaching into the point of operation before the stroke or movement completes.