EPA Safe Drinking Water Act (40 CFR Part 141, Subpart I)

EPA Lead & Copper Rule Improvements (LCRI) Auditor

Audit public water system compliance under the EPA LCRI final rule. Enforce the lowered 10 ppb lead action level, calculate the 10-year 100% lead service line replacement pace, and audit tap sampling.

Water System Inventory & Sampling Data

LCRI Action Level lowered to 10.0 ppb (formerly 15.0 ppb).
Copper Action Level remains 1.3 ppm.
Mandatory 10% annual average rate required under LCRI.

Statutory Compliance Audit Results

SYSTEM IN FULL LCRI COMPLIANCE
Lead 90th percentile is below the 10 ppb action level. Replacement pace meets mandate.
Total Lines Requiring Replacement
4,300 Lines
Required Annual Replacement
430 Lines/yr
Replacement Pace Status
Compliant (10.5%)
Lead Action Level Status
Compliant (7.8 ppb)

Regulatory Mandates (EPA LCRI Final Rule)

10 ppb Lowered Action Level
Trigger for mandatory public education and optimal corrosion control treatment (OCCT).
10-Year 100% LSL Replacement Mandate
Mandatory replacement of all lead and galvanized lines within 10 years (minimum 10%/year).
1st & 5th Liter Tap Sampling
Requires 5th liter sampling in homes with lead service lines to capture line stagnation.
🏠 Home Hub

Frequently Asked Questions (EPA LCRI Final Rule)

What is the new lead action level under the EPA LCRI final rule?
Under the EPA Lead and Copper Rule Improvements (LCRI) finalized in October 2024, the lead action level is lowered from 15 parts per billion (ppb or 0.015 mg/L) to 10 parts per billion (ppb or 0.010 mg/L). Exceeding this 90th percentile threshold mandates corrosion control treatment and public notification.
What is the mandatory service line replacement timeline under LCRI?
Under 40 CFR Part 141 Subpart I, water systems must replace 100 percent of lead service lines (LSLs) and galvanized service lines requiring replacement within 10 years of the compliance date, requiring a mandatory minimum rolling average replacement rate of at least 10 percent per year.
What updated tap sampling protocol does the LCRI require for lead service lines?
The LCRI requires water systems with lead service lines to collect both first-liter samples (reflecting interior building plumbing) and fifth-liter samples (reflecting water that has sat in the lead service line itself), utilizing whichever concentration is higher to calculate the 90th percentile compliance level.
What are the 24-hour public education requirements under LCRI?
If a water system exceeds the 10 ppb lead action level, it must issue a system-wide public notification within 24 hours to all consumers, and provide certified lead test results to individual households sampled within 3 business days.