RCRA Hazardous Waste Generator & Accumulation Auditor

Evaluate EPA Resource Conservation and Recovery Act (RCRA) generator classification under 40 CFR Part 262, on-site storage time limits (90 vs 180/270 days), accumulation caps, and federal enforcement penalty exposure.

1 kg ≈ 2.204 lbs (e.g., standard solvent wastes)
P-listed toxic chemicals (>1 kg triggers instant LQG status)
Total volume accumulated on-site today across all storage areas
Days elapsed since earliest container accumulation start date
≥200 miles permits SQGs to accumulate up to 270 days
Days accumulated past statutory deadline

Mandatory RCRA Compliance Elements Implemented

🏠 Home Hub

Statutory & Regulatory FAQs

What are the three hazardous waste generator categories under RCRA 40 CFR § 262.13?

Under RCRA regulations (40 CFR § 262.13): (1) Very Small Quantity Generator (VSQG): Generates ≤ 100 kg (approx 220 lbs) of non-acute hazardous waste and ≤ 1 kg of acute hazardous waste per calendar month; (2) Small Quantity Generator (SQG): Generates > 100 kg and < 1,000 kg (approx 220–2,200 lbs) of non-acute hazardous waste and ≤ 1 kg acute hazardous waste per month; (3) Large Quantity Generator (LQG): Generates ≥ 1,000 kg (approx 2,200 lbs) of non-acute hazardous waste or > 1 kg of acute hazardous waste per month.

What are the maximum accumulation time limits for hazardous waste without a TSDF permit?

Under 40 CFR Part 262: VSQGs have no statutory time limit as long as total on-site accumulation never exceeds 1,000 kg. SQGs may accumulate hazardous waste on-site without a permit for up to 180 days (or 270 days if the waste must be transported 200 miles or more to an off-site TSDF), provided total accumulation does not exceed 6,000 kg (40 CFR § 262.16). LQGs may accumulate hazardous waste on-site for no more than 90 days (40 CFR § 262.17).

What happens if a facility exceeds its accumulation time limit under RCRA?

A generator that stores hazardous waste on-site beyond the permitted accumulation time limits (90 days for LQGs, 180/270 days for SQGs) without an approved EPA extension automatically converts by operation of law into an unpermitted Treatment, Storage, and Disposal Facility (TSDF). This triggers severe civil enforcement penalties under RCRA Section 3008(a), which can exceed $93,753 per day per violation.

What are the rules for Satellite Accumulation Areas (SAAs) under 40 CFR § 262.15?

Under 40 CFR § 262.15, a generator may accumulate up to 55 gallons of non-acute hazardous waste or 1 quart of liquid (or 1 kg solid) acute hazardous waste at or near the point of generation and under the direct control of the operator. Once the 55-gallon or 1-quart threshold is reached, the container must be marked with the date and moved to the central accumulation area within 3 consecutive calendar days.