EPA Clean Water Act SPCC Oil Spill Prevention Plan Auditor
Evaluate applicability under 40 CFR Part 112, 1,320-gallon aboveground thresholds, Professional Engineer (PE) certification versus Tier I/II Qualified Facility self-certification, and secondary containment sizing.
Facility Oil Storage Parameters
Count all containers >= 55 gallons (drums, ASTs, totes, transformers).
Determines Tier I (<= 5,000 gal) vs Tier II or PE Plan.
Exempt if already regulated under federal UST program (40 CFR Part 280).
Mandatory review every 5 years under 40 CFR § 112.5.
SPCC Regulatory Audit Findings
SPCC Plan Mandated: Tier I Self-Certified
40 CFR Part 112 Applicability:Subject to SPCC Rule
Required Plan Certification Tier:Tier I Qualified Facility (Self-Certified)
PE Certification Required?Exempt (Owner Self-Certification Permitted)
5-Year Review Currency:Current (Valid for ~2.5 Years)
EPA Enforcement & Compliance Findings
The facility exceeds the 1,320-gallon aboveground threshold with 6,500 gallons total storage. Because total capacity is <= 10,000 gallons, no single container exceeds 5,000 gallons, and spill history is clean, the facility qualifies to use the streamlined EPA Tier I Qualified Facility Plan template without hiring a Professional Engineer.
EPA SPCC Regulatory & Legal FAQ
What types of oils are covered under the SPCC rule?
Under 40 CFR § 112.2, 'oil' is defined extremely broadly to include petroleum, fuel oil, sludge, oil refuse, motor oil, hydraulic fluid, synthetic oils, dielectric fluid in transformers, animal fats, and vegetable oils. All forms and derivatives are counted toward the 1,320-gallon threshold.
Do containers smaller than 55 gallons count toward the 1,320-gallon threshold?
No. Under 40 CFR § 112.1(d)(2), containers with a storage capacity of less than 55 U.S. gallons are completely excluded from the aggregate capacity calculation. However, all containers of 55 gallons or greater (including 55-gallon drums and 275/330-gallon IBC totes) must be counted toward the total.
What penalties does EPA impose for operating without an SPCC Plan?
Under Section 311 of the Clean Water Act (33 U.S.C. § 1321), EPA can assess administrative civil penalties of up to $22,363 per day for violations of the SPCC regulations, with statutory maximums exceeding $279,000 per enforcement action. In cases of unpermitted oil discharges to navigable waters, penalties increase drastically to over $55,000 per day or $2,200 per barrel discharged.
What is the difference between General Secondary Containment and Sized Secondary Containment?
Sized secondary containment (40 CFR § 112.8(c)(2)) applies to bulk storage containers (tanks) and must hold the entire capacity of the largest container plus freeboard for precipitation. General secondary containment (40 CFR § 112.7(c)) applies to loading/unloading racks and piping and requires appropriate sorbents, sumps, or curbing capable of holding the most likely discharge volume until cleanup occurs.
Environmental Compliance Notice: This audit application is provided for informational and preliminary screening purposes under EPA 40 CFR Part 112. State environmental protection agencies may enforce stricter standards, lower capacity thresholds, or mandatory professional engineer certifications regardless of federal tier status. Consult a qualified environmental engineer or legal counsel.
Embed or Share This Tool
Embed this EPA SPCC Auditor on your environmental platform: