OmniCalc Hub SDPWS Wood Shear Wall
🪵

Wood Shear Wall Design & Nailing Capacity Calculator (SDPWS / IBC 2021)

Calculate lateral seismic and wind shear resistance capacity for wood frame structural panel (WSP) shear walls: check height-to-width aspect ratio limits (3.5:1), edge nailing schedules (8d/10d), and design shear in PLF.

Individual full-height solid wall segment

Wood Shear Wall Design Summary (AWC SDPWS)

Aspect Ratio (h / b): 2.25 : 1 (Max 3.5:1 Allowed)
Aspect Ratio Reduction Factor (2b/h): 0.89 (Wind/Seismic adjusted)
Total Allowable Wall Segment Shear: 1,744 lbs (436 PLF)
Structural Capacity Status: PASS (109% of 1,600 lb Demand)