Payroll & HR

OSHA Permit-Required Confined Space (29 CFR 1910.146) Safety Entry Permit Generator

Generate OSHA 29 CFR 1910.146 Permit-Required Confined Space (PRCS) entry permits, validating 4-gas atmospheric testing parameters (Oxygen 19.5-23.5%, Combustible LEL < 10%, H2S < 10 ppm, CO < 35 ppm), LOTO verification, attendant duty checklists, and non-entry tripod rescue protocols.


% O2
OSHA Safe: 19.5% to 23.5%
% LEL
OSHA Max: < 10% LEL
ppm
OSHA PEL: < 10 ppm
ppm
OSHA PEL: < 35 ppm

Frequently Asked Questions

Under OSHA 29 CFR 1910.146, a Permit-Required Confined Space (PRCS) is a space that: (1) Is large enough and so configured that an employee can bodily enter; (2) Has limited or restricted means for entry or exit (e.g., manholes, tanks, vaults); (3) Is not designed for continuous employee occupancy; AND (4) Contains or has the potential to contain a hazardous atmosphere, engulfment hazard, or internal converging walls that could trap or asphyxiate an entrant.

Before any employee enters, the atmosphere must be tested with a calibrated instrument in the following specific order: (1) Oxygen content between 19.5% and 23.5%; (2) Flammable gases/vapors below 10% of the Lower Explosive Limit (LEL); (3) Hydrogen sulfide (H2S) below 10 ppm; and (4) Carbon monoxide (CO) below 35 ppm. Testing must be performed at top, middle, and bottom strata because gases stratify based on vapor density.

No. OSHA 29 CFR 1910.146(i)(4) strictly prohibits the standby attendant from entering the confined space for rescue. Over 60% of confined space fatalities in the United States are would-be rescuers who enter without self-contained breathing apparatus (SCBA). The attendant's sole duty is to operate non-entry retrieval equipment (tripod winch and harness) and summon professional rescue teams.
🏠 Home Hub