Audit confined space safety under OSHA 29 CFR 1910.146 and 29 CFR 1926 Subpart AA. Check 4-gas atmospheric safety limits (O2, LEL, CO, H2S), lockout/tagout isolation, and generate an official OSHA Confined Space Entry Permit.
OSHA Safe: 19.5% - 23.5%
OSHA Safe: < 10.0% LEL
OSHA PEL: < 25 ppm
OSHA PEL: < 10 ppm
Frequently Asked Questions
Under OSHA 29 CFR 1910.146, a 'Confined Space' is large enough for an employee to enter, has limited means of entry or exit, and is not designed for continuous occupancy. It becomes a 'Permit-Required Confined Space' (PRCS) if it has one or more of: (1) a hazardous or potentially hazardous atmosphere; (2) material with potential to engulf an entrant; (3) converging walls or sloping floors that could trap or asphyxiate; or (4) any other recognized serious safety hazard.
OSHA mandates testing in this exact chronological order: (1) Oxygen content (must be between 19.5% and 23.5%); (2) Flammable gases and vapors (must be below 10% of the Lower Explosive Limit - LEL); and (3) Toxic contaminants (such as Carbon Monoxide <= 25 ppm and Hydrogen Sulfide <= 10 ppm).
NO! OSHA 29 CFR 1910.146(i)(7) strictly prohibits the Attendant from entering the space to attempt a rescue. Historical data shows that over 60% of confined space fatalities are would-be rescuers. The Attendant must remain outside, summon the emergency rescue team, and operate the mechanical non-entry retrieval winch/tripod.
A non-entry retrieval system consists of a chest or full-body harness with a retrieval line attached at the center back, connected to a mechanical device (such as a tripod and winch) outside the space. OSHA requires non-entry retrieval systems for all vertical entries over 5 feet deep unless the equipment would increase overall risk or is physically impossible.