Statutory Compliance & Legal Guidance

A Type I Differing Site Condition occurs when subsurface or latent physical conditions encountered at the site differ materially from those indicated in the contract documents, geotechnical baseline reports (GBR), or boring logs. A Type II condition occurs when physical conditions encountered are unknown, unusual, and differ materially from those ordinarily encountered and generally recognized as inhering in work of the character provided for in the contract.

Under United States v. Spearin (1918), an owner impliedly warrants that the plans, specifications, and boring logs provided are reasonably accurate. If a contractor reasonably relies on inaccurate soil boring logs or misleading site indications, the owner bears financial responsibility for the resulting cost overruns and delays.

Under federal clause FAR 52.236-2 and state counterparts such as California Public Contract Code § 7104, a contractor must give prompt written notice before the conditions are disturbed. Failure to give notice prejudices the owner's ability to investigate the condition, evaluate alternative engineering solutions, or verify actual costs, often waiving the claim entirely.

A contractor is entitled to an equitable adjustment covering: (1) direct equipment and labor costs required to overcome the condition (e.g., rock ripping, dewatering, hazmat remediation), (2) jobsite and home office overhead for critical path delays, (3) reasonable profit on the additional work, and (4) an extension of contract completion time excusing liquidated damages.

Under California Public Contract Code § 7104, any local public works contract involving excavations deeper than 4 feet must contain a mandatory clause requiring immediate notification of: hazardous waste, subsurface/latent physical conditions differing from contract indications, or unknown physical conditions of an unusual nature.