Septic Perc Test & Drainfield Trench Sizing Calculator
Size residential septic absorption fields, chamber systems, and gravel trenches using county health department percolation test results and daily design wastewater flows.
Site & Soil Data
Rapid sand: 1-10; Silt loam: 20-45; Clay: 60+ (Severe)
Drainfield Sizing & Trench Layout
Total Trench Length
0 LF
3 runs of 0 ft
Drainfield Area
0 Sq Ft
Trench bottom absorption area
Daily Design Flow
480 GPD
Septic tank min: 1,250 Gal
Hydraulic Application Loading Rate:
0.00 GPD / sq ft
Recommended Septic Tank Working Capacity:
1,250 Gallons
Percolation Suitability Rating:
Good / Moderate
Recommended Trench Configuration:
4 trenches × 65 ft (100 ft max per run)
EPA & State Health Perc Rate Loading Formulations
Hydraulic application rate (Q) is determined from the perc rate (t in minutes per inch) using standard EPA sanitary engineering equations:
Application Rate = 5 ÷ √MPI (capped between 0.20 and 1.20 GPD/sq ft)
Absorption Area (sq ft) = Daily Design Flow (GPD) ÷ Application Rate
Trench Length (Linear Ft) = Absorption Area ÷ Trench Width (ft) × Chamber Factor
Absorption Area (sq ft) = Daily Design Flow (GPD) ÷ Application Rate
Trench Length (Linear Ft) = Absorption Area ÷ Trench Width (ft) × Chamber Factor