Commercial Kitchen Hood & Grease Duct Velocity Calculator
Calculate Type I kitchen commercial grease hood exhaust CFM, duct air velocity (FPM), and 80-90% makeup air per NFPA 96 and International Mechanical Code (IMC).
Hood & Cooking Appliance Specifications
×
Velocity & Code Compliance Verdict
Grease Duct Air Velocity
--
--
Design Exhaust Airflow
--
--
Dedicated Makeup Air (85% MUA)
--
15% Room Infiltration Transfer
Duct Cross-Sectional Area
--
--
NFPA 96 (Chapter 8) & IMC 506 Standards:
- NFPA 96 historical rule: Minimum duct air velocity of 1,500 FPM (prevents grease condensation and pooling).
- Maximum recommended velocity: 2,500 FPM to prevent excessive static pressure and fan breakout noise.
- Grease ducts must be continuously welded liquid-tight 16-gauge carbon steel or 18-gauge stainless steel.