US Post-Tensioned Concrete Flat Plate Punching Shear Calculator (ACI 318-19)

Calculate two-way punching shear stress, vertical prestress tendon force component Vp, concrete two-way shear strength Vc with average effective prestress fpc, and evaluate headed stud shear reinforcement per ACI 318-19 Section 22.6.

Design Input Parameters

Engineering Calculations & Results

Critical Shear Perimeter (b0 @ d/2): 102.0 inches
Ultimate Punching Shear Stress (vu): 189.5 psi
Design Punching Shear Strength (phi*Vn): 184.2 kips
Prestress Tendon Drape Uplift (Vp): +18.0 kips (7.3%)
Demand-to-Capacity Ratio (DCR): 0.79

Ready: Enter system parameters and calculate.

Engineering References & Methodology

This calculation engine applies standard formulas from ASHRAE, ACI 318-19, NFPA 68, FHWA, and NEC 625. All outputs are intended for professional engineering preliminary estimation, sizing, and peer design review.