Back to Hub Air Quality & Chemical Engineering

US Industrial Wet Scrubber Gas Absorption NTU & HTU Height Calculator

Calculate Number of Transfer Units (NTU), Height of a Transfer Unit (HTU, feet), and required packed bed depth (Z = NTU * HTU) for packed tower wet scrubbers removing acid gases (SO2, HCl, NH3, VOCs) per EPA Air Pollution Control Cost Manual and Perry's Chemical Engineers' Handbook.

Design Input Parameters

Engineering Calculations & Results

Clean Gas Outlet Concentration (y2): 18.0 ppmv (98.5% removal)
Number of Transfer Units (NTU): 4.20 transfer units
Recommended Design Packed Bed Height (Z): 11.6 feet (9.2 ft theoretical)
Scrubber Tower Internal Shell Diameter: 7.4 ft ID (89 in. shell)
Total Packing Media Volume Required: 498 cu. ft
Estimated Packing Bed Pressure Drop: 2.55 in. w.g.

Ready: Enter system parameters and calculate.

Engineering References & Methodology

This calculation engine applies standard engineering equations from ASHRAE, PCI, EPA, ACI 336, and California Title 24 standards. All outputs are intended for professional engineering estimation, sizing, and peer design review.