OmniCalc Hub ACCA Manual D & SMACNA Standard

HVAC Duct Static Pressure & CFM Sizing Calculator

Size supply trunks, return ducts, and branch runs compliant with ACCA Manual D static pressure budgets and maximum quiet velocity thresholds.

Blower & Run Parameters

e.g. 400 CFM/ton × 3 tons = 1,200 CFM
Total External Static Pressure rating
Component Pressure Drops (in. w.g.)
Air Filter Drop:
Evaporator Coil Drop:
Supply / Return Grilles & Dampers:
Straight duct + fitting equivalent feet
Joist bay ceiling height limit

Manual D Friction Rate & Sizing Results

Available Static Press. 0.00 in. wg Net pressure for ductwork
Design Friction Rate 0.000 in. w.g. / 100 ft
Round Duct Diameter 0.0 in Standard round spiral
Total Component Static Pressure Deduction: 0.00 in. w.g.
Equivalent Rectangular Duct Size: 0" × 0" (W × H)
Calculated Air Velocity: 0 FPM
Acoustic & Turbulence Rating: Acceptable

ACCA Manual D Friction Rate Formulation

The available static pressure (ASP) represents the pressure remaining after accounting for fixed appliance components (cooling coil, filter, backdraft dampers, registers). The friction rate (FR) dictates duct sizing across the total equivalent length (TEL):

ASP = TESP - (Filter + Coil + Grille/Dampers)
Friction Rate (FR) = (ASP × 100) ÷ Total Equivalent Length (TEL)
🏠 Home Hub