Level 2 EV Charger Circuit Breaker & Wire Gauge (NEC 625) Calculator

Calculate dedicated 240V circuit breaker size (80% continuous load rule), copper wire gauge (THHN vs Romex NM-B), and conduit sizing under NEC Article 625 for Tesla, ChargePoint, and universal Level 2 EV charging stations.

Calculation & Generation Results

Dedicated Double-Pole 240V Breaker 60 Amp Breaker (125% Rule)
Minimum Required Copper Conductor #6 AWG Copper
One-Way Voltage Drop (%) 0.86% (Safe, < 3% NEC limit)
Recommended PVC / EMT Conduit Size 3/4" or 1" Conduit
NEC Article 625 Compliance Code Summary
Under NEC Article 625.41, electric vehicle supply equipment is considered a continuous load. Overcurrent protection must be sized at 125% of the continuous charging current.

About This Tool

Calculate dedicated 240V circuit breaker size (80% continuous load rule), copper wire gauge (THHN vs Romex NM-B), and conduit sizing under NEC Article 625 for Tesla, ChargePoint, and universal Level 2 EV charging stations.

🏠 Home Hub

Frequently Asked Questions

What does the NEC continuous duty 125% rule mean for EV chargers?

Under National Electrical Code (NEC) Article 625.41, EV charging is defined as a continuous load (drawing maximum current for 3 hours or longer). Electrical breakers can only be loaded continuously to 80% of their rating. Therefore, a 48-amp charger requires a 60-amp breaker (48A × 1.25 = 60A), and a 40-amp charger requires a 50-amp breaker.

Can you run 48-amp EV charging through a NEMA 14-50 outlet?

No. The maximum continuous charging rate permitted through a standard NEMA 14-50 receptacle on a 50A breaker is 40 amps (80% of 50A). To charge at 48 amps (11.5 kW), the charger MUST be permanently hardwired directly to a dedicated 60A circuit.