FHWA GEC-010 / AASHTO
Drilled Shaft & Pier Axial Capacity Calculator
Calculate nominal side friction, base end bearing, and allowable compressive axial resistance for deep foundation drilled shafts per FHWA GEC-010 and AASHTO LRFD.
Shaft & Soil Parameters
Capacity & Resistance Breakdown
Allowable Axial Capacity (ASD)
--
--
Ultimate Side Resistance (Qs)
--
--
Ultimate End Bearing (Qp)
--
--
Total Ultimate Resistance (Qult)
--
--
Engineering Design Notes (FHWA-NHI-10-016):
- Top 5.0 ft (1.5 m) side friction is excluded for seasonal moisture fluctuation per FHWA.
- Bottom 1 diameter (B) side resistance above shaft tip is neglected due to stress overlap.
- Base bearing Nc = 9.0 applied for cohesive deep foundations (L/D > 3.0).