Back to Hub Geotechnical Deep Foundations

US Drilled Shaft Axial Rock Socket Capacity Calculator (FHWA GEC 010)

Calculate nominal and factored axial compressive resistance of drilled shafts rock sockets, evaluating side shear resistance (qs) and base end bearing resistance (qp) in rock formations per FHWA-NHI-18-024 (GEC 010) and AASHTO LRFD.

Design Input Parameters

Engineering Calculations & Results

Total Factored Axial Resistance (Rr): 7,458 kips (3,729 tons)
Nominal Side Socket Resistance (Rn_side): 4,260 kips (qs = 24.2 ksf)
Nominal Tip End Bearing (Rn_base): 10,230 kips (qp = 814.0 ksf)
Factored Side Resistance (phi*Rn_s): 2,343 kips (31% total)
Factored Base Resistance (phi*Rn_b): 5,115 kips (69% total)

Ready: Enter system parameters and calculate.

Engineering References & Methodology

This calculation engine applies standard engineering equations from ASHRAE, AASHTO LRFD, ASME PTC 4.1, FHWA, and IGSHPA guidelines. All outputs are intended for professional engineering estimation, sizing, and peer design review.