Commercial Kitchen Grease Interceptor Sizing Calculator

Size commercial restaurant hydromechanical grease interceptors (HGI) and outdoor gravity grease interceptors (GGI) per Uniform Plumbing Code (UPC) formulas.

Kitchen Plumbing Fixtures & Flow
Interceptor Capacity & Pumping Schedule
Recommended Minimum Rating
--
--
Grease Storage Capacity
--
ASME A112.14.3 Tested Minimum
Calculated Peak Drainage Flow
--
--
Cleanout Pumping Frequency
--
Based on 25% Rule (UPC 1014.3.4)

Uniform Plumbing Code (UPC Table 1014.2.1):

  • HGI rated flow (GPM) must equal or exceed 75% of connected fixture drainage volume emptied in 1.5 minutes.
  • Hydromechanical units must retain a minimum of 2 pounds of grease per 1 GPM flow rating.
  • Gravity interceptors must provide minimum 30-minute hydraulic retention time with 2-hour settling.