Subpanel Wire Size & Conduit Sizing Calculator (NEC)

Calculate electrical wire gauge (AWG/kcmil), conduit trade size, and voltage drop for 50A, 60A, 100A, and 125A garage, shed, or workshop electrical subpanels according to the National Electrical Code (NEC).

Calculation & Generation Results

Recommended Hot Wire Gauge: #1 AWG Aluminum
Neutral & Ground Wire Sizes: #1 Neutral, #6 Bare Ground
Calculated Voltage Drop (at 80% continuous): 1.48% (Well under 3% NEC limit)
Minimum Schedule 40 PVC Conduit: 1-1/2" Trade Size

About This Tool

Calculate electrical wire gauge (AWG/kcmil), conduit trade size, and voltage drop for 50A, 60A, 100A, and 125A garage, shed, or workshop electrical subpanels according to the National Electrical Code (NEC).

🏠 Home Hub

Frequently Asked Questions

Must the neutral and ground bars be separated in a subpanel?

Yes! Unlike the main service panel where neutral and ground share a bonded busbar, a subpanel MUST have an isolated neutral busbar with the bonding screw removed, and grounds tied to a separate grounded busbar to prevent hazardous parallel neutral return paths.

Why use aluminum MHF wire instead of copper?

Mobile Home Feeder (MHF) 2-2-4-6 or 1/0-1/0-1/0-2 aluminum wire costs 70% to 80% less than equivalent heavy copper cable and is safe, durable, and standard for garage and outbuilding underground feeders.