Structural Steel Base Plate with Large Moment (AISC Design Guide 1) Calculator
Design structural steel column base plates subjected to large axial loads and high overturning moments per AISC Design Guide 1 and AISC 360-22, calculating anchor rod tensile forces, concrete bearing stress, and minimum base plate thickness.
🔩 Column Loads & Base Plate Geometry
AISC DG-1 Large Moment Limit States
Load Eccentricity (e = Mu / Pu)
9.5 in (e > N/6)
Anchor Rod Tension (Tu)
34.8 kips
Max Concrete Bearing Stress
1,820 psi
Required Plate Thickness (tp)
1.625" (1-5/8" tp)
AISC Base Plate Specification Recommendation
22" x 18" x 1-3/4" Plate (A36 Steel) with 4x 1-1/4" Gr. 55 Anchor Rods