AISC Design Guide 1 / Base Plates
Structural Steel Column Base Plate Large Overturning Moment (AISC Design Guide 1) Calculator
Design structural steel column base plates under combined axial load (P_u) and large overturning moment (M_u, e > N/6) per AISC Design Guide 1: calculate concrete triangular bearing prism (Y), anchor rod tension (T_u), and required plate thickness (t_p).
📐 Loads & Base Plate Geometry (AISC DG1)
AISC DG1 Large Eccentricity Results
Eccentricity e & Regime
0.0 in
e > N/6 (Tension in Bolts)
Anchor Rod Tensile Demand T_u
0 kips
Total Uplift Force
Min Base Plate Thickness t_p
0.00 in
Bending Overhang Check