OmniCalc Hub Energy Storage

Solar Battery Backup Runtime Calculator

Plan home resilience during grid blackouts. Computes continuous runtime hours, critical load demand (Watts), depth of discharge (DoD), and solar recharge replenishment.

Battery Bank & Critical Loads

E.g., Fridge (150W avg) + Wi-Fi (25W) + LED lights (100W) + Well pump (200W avg) + TV (120W) = ~600W.
Enter 0 for dark winter storm outage.
Estimated Battery Runtime (No Sun)
18.1 Hours
Daily Critical Load Consumption: 15.6 kWh / 24 hrs
Usable Stored Energy: 11.80 kWh Delivered
With Solar Recharge (12 kWh): 3.3 Days Autonomy
Nominal Battery Pack: 13.5 kWh Nameplate
Inverter Tare Loss: ~8% Conversion Loss
Grid Outage Plan: At 650W continuous draw, a single 13.5 kWh battery provides 18.1 hours of power during a complete blackout without solar. With 12 kWh of daytime solar replenishment, your critical circuits will run indefinitely in sunny weather.

Energy Storage Sizing Rules:

• Formula: Runtime (Hours) = (Nameplate kWh × DoD × Inverter Efficiency × 1000) / Continuous Watts.

• Surge vs Continuous: Starting an air conditioner or well pump requires 3,000–5,000 surge watts for 1–2 seconds. Ensure battery continuous inverter output (typically 5 kW to 7.6 kW per battery) handles motor locked-rotor amps (LRA).