Retaining Wall Geogrid Sizing Calculator
Size uniaxial and biaxial geogrid soil reinforcement for segmental block retaining walls (SRW) taller than 4 feet according to National Concrete Masonry Association (NCMA) standards.
Wall Dimensions & Soil
Required Geogrid Length
5.6 Ft Length
70% of total height (Minimum 4.0 ft embedment into backfill)
Total Geogrid Layers:
4 Reinforcement Layers
Vertical Spacing:
Every 2 Courses (16" O.C.)
Buried Base Block:
1.0 Ft (1.5 Blocks Below Grade)
Excavation Depth:
6.5 Ft Behind Wall Face
NCMA Compliant Layout: Install layers at Course 2, 4, 6, and 8. Extend geogrid continuously 5.6 ft back into well-compacted gravel backfill. Never lap geogrid in the strength direction.
NCMA Design Standards:
• Embedment Ratio: Grid length must be at minimum 60% of total height (0.6H) for level crests, increasing to 70%–80% for vehicular surcharges or backslopes.
• Maximum Vertical Spacing: Never exceed 24 inches or two times the block depth between geogrid layers to prevent local block toppling.