IBC 2024 / ACI 318-19 Retaining Wall
Reinforced Concrete Cantilever Retaining Wall Stem & Stability Calculator
Calculate Rankine/Coulomb lateral active earth pressure, overturning safety factor (FSot >= 1.50), base sliding resistance (FSsl >= 1.50), soil bearing pressure eccentricity, and cantilever stem bending moment per IBC 2024 and ACI 318-19.
🧱 Wall Geometry & Soil Mechanics Parameters
Rankine Ka Coeff
0.307
(1-sin φ)/(1+sin φ)
FS Overturning
2.41
PASS (>= 1.50)
FS Sliding
1.62
PASS (>= 1.50)
Max Toe Pressure, qmax
2,410 psf
PASS (< qa)
Stability Forces & Stem Reinforcement Breakdown
| Component | Force / Weight (lb/ft) | Lever Arm from Toe (ft) | Resisting Moment (lb-ft/ft) | Overturning Moment (lb-ft/ft) |
|---|