ACI 318-19 Punching Shear
Reinforced Concrete Two-Way Slab Punching Shear (ACI 318-19 Section 22.6) Calculator
Calculate two-way flat plate punching shear stress v_ug, critical perimeter b_o, concrete nominal shear capacity v_c with size effect factor lambda_s, and shear reinforcement requirements per ACI 318-19.
🏢 Slab Geometry & Column Connection
⚡ Factored Shear Demand & Concrete Materials
ACI 318-19 Two-Way Punching Shear Capacity
Critical Perimeter b_o
100.0 in
Located at d/2 from face
Applied Stress v_uv
164.3 psi
v_u = V_u / (b_o * d)
Design Strength phi*v_c
201.2 psi
phi*V_c = 140.9 kips
Demand / Capacity Ratio
0.82
ADEQUATE (PASS)
ACI 318-19 Size Effect Factor lambda_s = sqrt(2 / (1 + 0.004 * d)):
1.00
Governing ACI Equation (Eq 22.6.5.2a / b / c):
Eq (a): 4 * lambda_s * lambda * sqrt(f'c)
Shear Reinforcement (SSR / Stud Rails) Requirement:
Not Required (Concrete alone resists punching shear)