Radiant Floor PEX & BTU Sizing Calculator
Size hydronic radiant floor heating installations. Calculates required linear feet of PEX tubing, manifold loop count, balancing flow rate (GPM), and boiler heating output.
Room & Heating Parameters
Total PEX Tubing Required
967 Linear Ft
1.33 ft PEX per sq. ft. of floor area + leads
Required Manifold Ports:
4-Port Manifold (4 Loops)
Avg Loop Length:
242 Ft / loop (< 300' limit)
Total Heat Demand:
16,250 BTU/hr (4.76 kW)
Hydronic Flow Rate (GPM):
1.63 GPM (20°F ΔT)
Hydronic Industry Best Practices (RPA / ASHRAE):
• Max Loop Limit: 1/2-inch PEX must never exceed 300 feet per loop to prevent extreme friction head loss and cold floor zones.
• Flow Rate Equation: GPM = Total BTU/hr / (500 × ΔT). For standard radiant floors operating at a 20°F temperature drop (ΔT), each 10,000 BTU/hr requires exactly 1.0 GPM.