EV Charger Panel & Breaker Calculator

Verify electrical panel capacity for Level 2 electric vehicle charging (EVSE). Computes 125% continuous load breaker size, copper conductor gauge, and amp headroom per NEC § 625.42 and § 220.

Panel & EV Charger Specs

Required Dedicated Circuit Breaker
60 Amp 2-Pole
11.52 kW Continuous Draw (125% Rule Applied)
Min. Copper Conductor: #6 AWG THHN / #4 NM-B
Total Combined Panel Load: 175 A / 200 A
Remaining Headroom: 25.0 Amps (12.5% Margin)
Panel Capacity Assessment: PASS: Safe to Install
Total calculated demand with EVSE is within safe 80% continuous panel threshold. No 200A service upgrade required.

NEC Code Compliance Rules:

• NEC § 625.42: Electric vehicle charging is classified as a continuous load (runs 3+ hours). Overcurrent protection devices (breakers) must be sized at minimum 125% of the charger's rated output.

• Smart EVEMS Alternative: If panel capacity is insufficient, an Energy Management System (e.g. Wallbox Pulsar with Power Meter) avoids a costly $3,000+ panel replacement by throttling charging during oven/HVAC peaks.