OmniCalc Hub NEC 220.82

NEC Article 220.82 Residential Service Load Calculator

Standard National Electrical Code (NEC) single-family dwelling optional calculation. Sizes main electrical service panels (100A, 150A, 200A, or 400A) based on general loads, kitchen appliances, and HVAC.

Home Area & Connected Loads

NEC Service Sizing Results

Recommended Panel
200 Amp Service
Total Calculated Amps
146.4 Amps
Demand Load (VA)
35,140 VA
General Lighting Load (2,600 sq.ft × 3 VA): 7,800 VA
General Loads Demand (First 10k @ 100%, Remainder @ 40%): 24,340 VA
Cooling / Heating (100% of Largest HVAC Load): 6,500 VA
Continuous EV Charging Load (100%): 9,600 VA
🏠 Home Hub