Calculation & Generation Results
About This Tool
Calculate hourly fuel burn rates (Gallons/hr & CFH), runtime duration on 250/500-gallon propane tanks, and operating fuel costs across 10kW to 26kW whole-house standby generators.
Frequently Asked Questions
Why can propane tanks only be filled to 80% capacity?
Under National Fire Protection Association (NFPA 58) rules, liquid propane tanks are filled to a maximum of 80% to allow space for vapor expansion as ambient outdoor temperatures rise.
Why does a 22kW generator produce less power on Natural Gas than Propane?
Natural gas contains roughly 1,010 BTU per cubic foot, whereas liquid propane yields 2,516 BTU per cubic foot. Because of this energy density difference, standby generators are typically derated by 10% to 15% when operating on natural gas.
How long can a whole-house generator run continuously during an extended blackout?
Modern whole-house generators are designed to run continuously for weeks, but manufacturers specify that engine oil and filters MUST be changed every 100 to 200 continuous operating hours.