← Back to All Tools
💧

Yard French Drain Pipe, Gravel & Filter Fabric Calculator

Calculate perforated drainage pipe linear feet, #57 washed drainage gravel tonnage, and non-woven geotextile filter fabric square footage for yard, basement, and retaining wall water redirection.

Calculation & Generation Results

#57 Washed Gravel Backfill 7.4 Tons (5.5 Cu Yds)
Non-Woven Geotextile Filter Fabric 560 Sq Ft (e.g. 6 ft x 100 ft Roll)
Perforated Pipe Length 80 Linear Feet
Slope & Installation Standard
Maintain a minimum 1% downward slope (1 inch drop per 8 to 10 feet of run) and install perforated holes facing DOWN into 2 inches of gravel bed.

About This Tool

Calculate perforated drainage pipe linear feet, #57 washed drainage gravel tonnage, and non-woven geotextile filter fabric square footage for yard, basement, and retaining wall water redirection.

🏠 Home Hub

Frequently Asked Questions

Why should perforated holes face DOWN in a French drain pipe?

Water rises from the bottom of the gravel trench into the pipe. When holes face down, rising water enters the pipe at the lowest elevation and drains away immediately. If holes face up, water must fill the entire gravel trench before draining, leaving stagnant water behind.

Why is non-woven geotextile fabric mandatory around the entire trench?

Wrapping the entire gravel envelope in non-woven needle-punched geotextile fabric prevents surrounding clay and silt soils from migrating into and clogging the voids between gravel stones.