Modified Rational & Outlet Hydraulics
Commercial Stormwater Detention Pond Routing & Hydrograph Calculator
Compute pre- and post-development peak stormwater runoff using the Rational Method (Q = C*I*A), determine required storage volume via Modified Rational Method, and size multi-stage orifice and weir discharge structures.
🌊 Watershed Hydrology & Basin Sizing
Pre-Dev Peak Flow (Qpre)
8.19 CFS
Allowable release rate
Post-Dev Peak (Qpost)
19.19 CFS
+134% peak increase
Required Storage (Vreq)
13,200 cu ft
0.303 acre-feet
Low-Flow Orifice Dia
12.4 in
Limits discharge <= Qpre
Basin Geometry & Multi-Stage Hydraulic Outlets
Detention Basin Earthwork Sizing:
Required Water Volume: 13,200 cu ft (98,740 gal)
Bottom Surface Footprint: 2,600 sq ft (~51 ft x 51 ft)
Top Water Surface Footprint: 4,900 sq ft (~70 ft x 70 ft)
Freeboard Minimum (IBC/NRCS): 1.0 ft above max ponding depth
Primary & Emergency Spillway Control:
Low-Stage Orifice Invert: Pond bottom, h = 4.0 ft head
Orifice Design Discharge: 8.19 CFS
Emergency Weir Crest Length: 6.2 ft (for 100-yr 1.5 ft head)
Drawdown Time (Est): 24 - 36 hours