Attic Ventilation & Soffit-to-Ridge (1:150 vs 1:300 Rule) Calculator

Calculate required Net Free Vent Area (NFVA) for attics under IRC Section R806, splitting continuous intake soffit vents (50%) and exhaust ridge vents (50%).

Calculation & Generation Results

Total Required Net Free Vent Area (NFVA) 1,056 sq in (7.33 sq ft)
Intake Soffit Vent NFVA (50%) 528 sq in
Exhaust Ridge Vent NFVA (50%) 528 sq in
Ridge Vent Rating Required (NFVA / Linear Foot) 11.0 sq in / lin. ft

About This Tool

Calculate required Net Free Vent Area (NFVA) for attics under IRC Section R806, splitting continuous intake soffit vents (50%) and exhaust ridge vents (50%).

🏠 Home Hub

Frequently Asked Questions

What is Net Free Vent Area (NFVA)?

Net Free Vent Area (NFVA) is the actual unobstructed open area through which air can pass in an attic vent, accounting for wire mesh screens, louvers, and baffles that typically block 30% to 50% of the gross opening.

Why does the International Residential Code (IRC) prefer balanced 50/50 ventilation?

Under IRC Section R806.2, balancing 50% low intake at the eaves/soffits with 50% high exhaust at the ridge creates a natural passive convection chimney effect. If you have too much exhaust and insufficient intake, the ridge vents can pull conditioned air out of the living space below or draw rain into the attic.