OmniCalc Hub AASHTO Pavement
🛣️

Asphalt Pavement Structural Number (SN) & ESAL Design Calculator (AASHTO 1993)

Calculate flexible asphalt pavement Structural Number (SN), layer thicknesses (HMA surface, crushed stone base, subbase), and traffic loading capacity based on AASHTO 18-kip Equivalent Single Axle Loads (ESALs).

Poor clay ~3,000 psi; Silt ~5,000 psi; Sandy gravel ~10,000 psi
Layer coeff a1 = 0.44 per inch (HMA Superpave)
Layer coeff a2 = 0.14 per inch (Dense graded stone)
Layer coeff a3 = 0.11 per inch (Select granular borrow)

AASHTO Flexible Pavement Structural Analysis

Provided Structural Number (SN): 3.32
Required Structural Number (SN_req): 3.15 (SUFFICIENT)
Total Pavement Section Depth: 17.5 inches
Pavement Structural Reserve: +5.4% Capacity
🏠 Home Hub