NCEES PE Civil / AWC NDS 2024 Time: 00:00

PE Civil: Structural Timber & Wood Design (NDS 2024) Practice Exam

Master NCEES PE Civil structural timber questions: AWC NDS 2024 reference design values, adjustment factors (CD, CM, Ct, CL, CV), beam flexure, column buckling (CP), and dowel fastener yield limit equations.

Question 1: Under the AWC National Design Specification (NDS) for Wood Construction, what is the Load Duration Factor (CD) for load combinations where the controlling transient load is wind or seismic load?
Question 2: When designing a glued laminated timber (glulam) beam, which two adjustment factors CANNOT be applied simultaneously to the reference bending design value (Fb)?
Question 3: In sawn lumber design, when is the Wet Service Factor (CM) applied to reduce reference design values?
Question 4: In determining the Column Stability Factor (CP) for a rectangular solid sawn wood column with effective length Ke*L and cross-sectional dimension d, what is the maximum allowable slenderness ratio (Ke*L / d)?
Question 5: Under NDS Section 3.4.3.1, when calculating the design shear force V' for a solid rectangular wood beam subjected to transverse loading, loads located within what distance from the support face may be neglected?
Question 6: What does the Repetitive Member Factor (Cr = 1.15) account for in light-frame wood floor and roof construction?
Question 7: When calculating the allowable bearing capacity perpendicular to grain (Fc-perp), how is the Bearing Area Factor (Cb) applied for bearing lengths of less than 6 inches located more than 3 inches from member ends?
Question 8: In the European Yield Model (EYM) for dowel-type fastener lateral connections (NDS Chapter 11), what does Yield Mode IV represent?
Question 9: Under IBC Chapter 16 and NDS recommendations, what is the standard serviceability deflection limit for floor joists supporting plaster or sensitive finishes under live load only?
Question 10: For long-term total load deflection calculations in unseasoned wood members subjected to permanent dead load, what long-term creep deflection factor (Kcr) is applied to the immediate dead load deflection?

Exam Blueprint & Psychometric Standard

This practice assessment simulates the cognitive rigor, psychometric test specifications, and scenario complexity of the official United States professional licensing examination.

Study Tip: Aim for a consistent score of 80% or higher under timed conditions before sitting for your official proctored testing appointment. Review both correct and incorrect rationales carefully.
🏠 Home Hub